{"subject":"[YangMing] Upright Microscope - Olympus BX63","detailContent":"<div class=\"ed_model05 clearfix\">\r\n<div class=\"ed_pic_right\"><img alt=\"Upright Motorized Fluorescence Microscope Olympus BX63\" src=\"/userfiles/ordch/images/20231013105418281.jpg\" /></div>\r\n\r\n<div class=\"ed_model01 clearfix\">\r\n<ul>\r\n\t<li class=\"ed_txt\"><strong>Motorized Upright Fluorescence Microscope</strong></li>\r\n\t<li class=\"ed_txt\"><strong>Instrument Location: </strong>Yang-Ming Campus\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><strong>Room B03, Floor B1, Shou-ren Building</strong></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Person in charge: YM Campus Imaging&nbsp;Core Facility</strong>\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\">Ms. Pei-Jun Chen&nbsp;<a href=\"mailto:pjchen3@nycu.edu.tw\" title=\"pjchen3@nycu.edu.tw\">pjchen3@nycu.edu.tw</a></li>\r\n\t\t<li class=\"ed_txt\">Ms. Yung-yu Lu&nbsp;<a href=\"mailto:yungyu@nycu.edu.tw\" title=\"yungyu@nycu.edu.tw\">yungyu@nycu.edu.tw</a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Term of&nbsp;use: Certification&nbsp;</strong>\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\">Only those who have passed the certification test after the instruction and have operated the device more than 5 times during office hours will be authorized to make a reservation.</li>\r\n\t\t<li class=\"ed_txt\"><strong>Free of charge for on-campus use.&nbsp;Please refer to the charging standard for off-campus use.</strong></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Reservation &gt;&gt;&gt; <a href=\"https://ircbooking.nycu.edu.tw/IRC/irc_booking/index_en.aspx\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Instrument Reservation System(Open New Windows)\">Instrument Reservation System</a></strong></li>\r\n</ul>\r\n</div>\r\n</div>","dataClassName":null,"pubUnitName":"Instrumentation Resource Center                                                                     ","posterDate":null,"updateDate":"2025-01-15","liaisonper":null,"liaisontel":"ext. 66185/65980","liaisonfax":null,"liaisonemail":null,"languageurl":null,"page1Title":"Instrument Specifications","page1":"<div class=\"ed_model01 clearfix\">\r\n<div class=\"ed_txt\"><strong>Microscope System:</strong></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">Olympus BX-63 Upright Electronic Control Microscope</li>\r\n\t<li class=\"ed_txt\">Color LCD touch panel</li>\r\n\t<li class=\"ed_txt\">BX3-SSU ultrasonic motorized stage (can hold two standard slides)</li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\"><strong>Objectives:</strong></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">1.25X, 4X, 10X, 20X, 40X</li>\r\n\t<li class=\"ed_txt\">100X (Oil)</li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\"><strong>Fluorescence&nbsp;Illumination&nbsp;System:</strong></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">X-cite TURBO LED</li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\"><strong>Observation Methods:</strong></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">Transmitted light: Bright Field (BF) and Differential Interference Contrast (DIC)</li>\r\n\t<li class=\"ed_txt\">Fluorescence: Fluorescence filter with ultraviolet light excitation, blue light excitation, yellow-green light excitation, and near-infrared light&nbsp;<a href=\"/userfiles/ordch/images/20231127111835702.jpg\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"BX63 filter sets(jpg)(Open New Windows)\"><strong>BX63 filter sets</strong></a>) (Note 1)<img alt=\"BX63 filter sets\" src=\"/userfiles/ordch/images/20231127111835702.jpg\" /></li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\"><strong>Camera:</strong></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">DP72 High-sensitivity cooled color CCD</li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\"><strong>Software:</strong></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">cellSens V2.3</li>\r\n\t<li class=\"ed_txt\">Including Dimension and Multi Position advanced modules</li>\r\n\t<li class=\"ed_txt\">Deconvolution: 2D, Nearest Neighbor and Wiener</li>\r\n</ul>\r\n</div>\r\n\r\n<div class=\"ed_model06 clearfix\">\r\n<div class=\"table01\">\r\n<table class=\"ed_table caption-top\" summary=\"2023/9/19更換新螢光燈源並更新一組快速螢光轉盤 89402 ET-Multi LED set\">\r\n\t<caption>Note 1. On 2023/9/19&nbsp;Replaced new fluorescent light source and updated a fast fluorescent turntable 89402 ET-Multi LED set</caption>\r\n\t<tbody>\r\n\t\t<tr>\r\n\t\t\t<th scope=\"col\">Method</th>\r\n\t\t\t<th scope=\"col\">LED</th>\r\n\t\t\t<th scope=\"col\">Mirror Unit</th>\r\n\t\t\t<th scope=\"col\">Excitation Filter</th>\r\n\t\t\t<th scope=\"col\">Dichromatic Mirror</th>\r\n\t\t\t<th scope=\"col\">Emission Filter</th>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Method\">DAPI</td>\r\n\t\t\t<td data-th=\"LED\">385</td>\r\n\t\t\t<td data-th=\"Mirror Unit\">89402 ET-Multi LED set</td>\r\n\t\t\t<td data-th=\"Excitation Filter\">391/32</td>\r\n\t\t\t<td data-th=\"Dichromatic Mirror\">410-458</td>\r\n\t\t\t<td data-th=\"Emission Filter\">418-450</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Method\">GFP</td>\r\n\t\t\t<td data-th=\"LED\">475</td>\r\n\t\t\t<td data-th=\"Mirror Unit\">89402 ET-Multi LED set</td>\r\n\t\t\t<td data-th=\"Excitation Filter\">479/33</td>\r\n\t\t\t<td data-th=\"Dichromatic Mirror\">497-540</td>\r\n\t\t\t<td data-th=\"Emission Filter\">505-530</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Method\">TRITC</td>\r\n\t\t\t<td data-th=\"LED\">525</td>\r\n\t\t\t<td data-th=\"Mirror Unit\">89402 ET-Multi LED set</td>\r\n\t\t\t<td data-th=\"Excitation Filter\">554/24</td>\r\n\t\t\t<td data-th=\"Dichromatic Mirror\">570-615</td>\r\n\t\t\t<td data-th=\"Emission Filter\">577-610</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Method\">Cy5</td>\r\n\t\t\t<td data-th=\"LED\">630</td>\r\n\t\t\t<td data-th=\"Mirror Unit\">89402 ET-Multi LED set</td>\r\n\t\t\t<td data-th=\"Excitation Filter\">638/31</td>\r\n\t\t\t<td data-th=\"Dichromatic Mirror\">655-730</td>\r\n\t\t\t<td data-th=\"Emission Filter\">663-725</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Method\">FITC-long</td>\r\n\t\t\t<td data-th=\"LED\">475</td>\r\n\t\t\t<td data-th=\"Mirror Unit\">U-FBW</td>\r\n\t\t\t<td data-th=\"Excitation Filter\">BP460-495</td>\r\n\t\t\t<td data-th=\"Dichromatic Mirror\">DM505</td>\r\n\t\t\t<td data-th=\"Emission Filter\">BA510IF</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Method\">mCherry</td>\r\n\t\t\t<td data-th=\"LED\">575</td>\r\n\t\t\t<td data-th=\"Mirror Unit\">U-FYW</td>\r\n\t\t\t<td data-th=\"Excitation Filter\">BP545-585</td>\r\n\t\t\t<td data-th=\"Dichromatic Mirror\">DM595</td>\r\n\t\t\t<td data-th=\"Emission Filter\">BA600IF</td>\r\n\t\t</tr>\r\n\t</tbody>\r\n</table>\r\n</div>\r\n</div>","page2Title":"Applications","page2":"<div class=\"ed_model01 clearfix\">\r\n<ul>\r\n\t<li class=\"ed_txt\">Bright field sample observation: HE staining, silver staining, etc.</li>\r\n\t<li class=\"ed_txt\">Fluorescent immunostaining samples</li>\r\n\t<li class=\"ed_txt\">Support 5D image capture (XYZ &lambda; T)</li>\r\n\t<li class=\"ed_txt\">Motorized Multi-Channel Scanner</li>\r\n\t<li class=\"ed_txt\">Multi Position: motorized multi-position or area&nbsp;scanning</li>\r\n\t<li class=\"ed_txt\">Z-slices: motorized Z-axis scan and EFI (extended depth of field) processing</li>\r\n\t<li class=\"ed_txt\">Simple manual measurement</li>\r\n</ul>\r\n</div>","page3Title":"Reservation and Rules","page3":"<div class=\"ed_model01 clearfix\">\r\n<div class=\"ed_txt\"><span style=\"color:#e74c3c;\"><span style=\"font-size:110%;\"><strong>*Users must be certified.</strong></span></span><br />\r\n<strong>Users should pass the certification test and operate the system more than 5 times (including) during office hours (8:30-16:30)</strong> before they are authorized to reserve online, and can use the system according to the regulations. If the certified user does not use the device for one month, he/she must be certified again by the administrator.<br />\r\n&nbsp;</div>\r\n\r\n<ol>\r\n\t<li class=\"ed_txt\"><strong>Reservation regulations</strong>:\r\n\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\">Please go to the <a href=\"https://ircbooking.nycu.edu.tw/IRC/irc_booking/index_en.aspx\" title=\"&quot;Instrument Reservation System&quot;\">&quot;Instrument Reservation System&quot;</a> to make a reservation before use. The person who makes the reservation must be the actual user.</li>\r\n\t\t<li class=\"ed_txt\">After use, please register in the record book. The start time is the reservation time, and the end time is based on the end time of use. You cannot delay the start time or occupy other people&#39;s time slots.</li>\r\n\t\t<li class=\"ed_txt\">Reservations cannot be canceled on the same day. Reservations made more than half an hour after the scheduled time are considered abandoned.</li>\r\n\t\t<li class=\"ed_txt\">No same-day reservations are accepted. Please confirm your reservation by 16:30 of the previous workday at the latest; late changes violate the rules and will not be accepted.</li>\r\n\t\t<li class=\"ed_txt\">Each person can make 4 reservations within two weeks, and each reservation can be made for 4 hours.</li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Sample requirements</strong>:\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><span style=\"color:#e74c3c;\">Fixed slide samples must be completely sealed before loading.</span></li>\r\n\t\t<li class=\"ed_txt\">Please be sure to clean slides before loading.</li>\r\n\t\t<li class=\"ed_txt\">Please ask the Instrument Center Administrator for assistance if you have any other needs or special usage requirements.</li>\r\n\t</ul>\r\n\t</li>\r\n</ol>\r\n</div>","page4Title":"Opening Hours","page4":"<div class=\"ed_model01 clearfix\">\r\n<ul>\r\n\t<li class=\"ed_txt\">Monday to Friday\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\">00:00-24:00 Restricted to Certified Users only<span style=\"display: none;\">&nbsp;</span></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\">weekend\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\">00:00-24:00 Restricted to Certified Users only</li>\r\n\t</ul>\r\n\t</li>\r\n</ul>\r\n</div>","page5Title":"Charges","page5":"<style type=\"text/css\">.horizontal-scroll-container {\r\n        overflow-x: auto; /* 允許水平滾動 */\r\n}\r\n</style>\r\n<!-- 螢光顯微鏡收費標準 -->\r\n<div class=\"table01 norwd  horizontal-scroll-container\">\r\n<table class=\"ed_table caption-top\" style=\"width:960px;\" summary=\"Instrument charges\">\r\n\t<caption>Instrument charges (NTD per hour)</caption>\r\n\t<tbody>\r\n\t\t<tr>\r\n\t\t\t<th scope=\"col\">Fluorescence Microscope</th>\r\n\t\t\t<th scope=\"col\">Slide scanner</th>\r\n\t\t\t<th scope=\"col\">Upright type</th>\r\n\t\t\t<th scope=\"col\">Inverted type<br />\r\n\t\t\tFor living cells</th>\r\n\t\t\t<th scope=\"col\">On Confocal Microscope<br />\r\n\t\t\tFor living&nbsp;cells&nbsp;</th>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Fluorescence microscope\">Model</td>\r\n\t\t\t<td data-th=\"Whole slide scanning system\" style=\"text-align: center;\">(Z) Axioscan 7</td>\r\n\t\t\t<td data-th=\"Upright\" style=\"text-align: center;\">(L) DM6000B<br />\r\n\t\t\t(O) BX61<br />\r\n\t\t\t<span style=\"color:#e74c3c;\">(O) BX63</span></td>\r\n\t\t\t<td data-th=\"For inverted living cells\" style=\"text-align: center;\">(O) IX83</td>\r\n\t\t\t<td data-th=\"Mounted on conjugate focus microscope for living cells\" style=\"text-align: center;\">(Z) LSM880&nbsp;with Airyscan<br />\r\n\t\t\t(Z) LSM900&nbsp;with Airyscan2</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"Fluorescence microscope\">Fees for NYCU faculty and students</td>\r\n\t\t\t<td data-th=\"Whole Slide Scanning System\" style=\"text-align: center;\">300</td>\r\n\t\t\t<td data-th=\"Upright\" style=\"text-align: center;\"><span style=\"color:#e74c3c;\">0</span></td>\r\n\t\t\t<td data-th=\"For inverted living cells\" style=\"text-align: center;\">100</td>\r\n\t\t\t<td data-th=\"Mounted on conjugate focus microscope for living cells\" style=\"text-align: center;\">300</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"fluorescence microscope\">Fees for cooperative educational units</td>\r\n\t\t\t<td data-th=\"Whole Slide Scanning System\" style=\"text-align: center;\">450</td>\r\n\t\t\t<td data-th=\"Upright\" style=\"text-align: center;\"><span style=\"color:#e74c3c;\">50</span></td>\r\n\t\t\t<td data-th=\"For inverted living cells\" style=\"text-align: center;\">150</td>\r\n\t\t\t<td data-th=\"Mounted on conjugate focus microscope for living cells\" style=\"text-align: center;\">450</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"fluorescence microscope\">Fees for other unit</td>\r\n\t\t\t<td data-th=\"Whole slide scanning system\" style=\"text-align: center;\">600</td>\r\n\t\t\t<td data-th=\"Upright\" style=\"text-align: center;\"><span style=\"color:#e74c3c;\">100</span></td>\r\n\t\t\t<td data-th=\"For inverted living cells\" style=\"text-align: center;\">200</td>\r\n\t\t\t<td data-th=\"Mounted on conjugate focus microscope for living cells\" style=\"text-align: center;\">600</td>\r\n\t\t</tr>\r\n\t\t<tr>\r\n\t\t\t<td class=\"ed_pc_center\" data-th=\"fluorescence microscope\">Remarks</td>\r\n\t\t\t<td colspan=\"3\" data-th=\"Whole slide scanning system\">\r\n\t\t\t<ol>\r\n\t\t\t\t<li>Abbreviation: (L) Leica, (O) Olympus, (Z) Zeiss</li>\r\n\t\t\t\t<li><strong>Number of Reservations: Each person can make four reservations per device within a two-week period, with a maximum of four hours per reservation. Reservations can be made consecutively on all devices.</strong></li>\r\n\t\t\t\t<li>Besides the imaging core facility education and training organized by the center, it is recommended that you bring your samples for scheduled teaching and certification exams (experimental data can be taken away), and the charges will be the same as for general use.</li>\r\n\t\t\t\t<li><strong>The above table shows the hourly usage charge. Charges are calculated on a half-hour basis.</strong></li>\r\n\t\t\t</ol>\r\n\t\t\t</td>\r\n\t\t\t<td data-th=\"Mounted on conjugate focus microscope for living cells\">Users must&nbsp;complete confocal microscope certification to use.</td>\r\n\t\t</tr>\r\n\t</tbody>\r\n</table>\r\n</div>\r\n\r\n<div class=\"ed_model01 clearfix\">\r\n<div class=\"ed_txt\">If you have the following qualifications, you will be charged the same fee as <strong>NYCU faculty and students</strong>:</div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">Branch school</li>\r\n\t<li class=\"ed_txt\">Joint-appointed faculty&nbsp;</li>\r\n\t<li class=\"ed_txt\">Affiliated hospitals&nbsp;</li>\r\n\t<li class=\"ed_txt\">Projects in cooperation with and under the control of the University.</li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\">If you have the following qualifications, the fee will be the same as that of a <strong>cooperative educational unit</strong>:</div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\">Adjunct faculty</li>\r\n\t<li class=\"ed_txt\">Teaching hospitals (Veterans General Hospital, Taipei City Hospital, Far Eastern Memorial Hospital, etc.)</li>\r\n\t<li class=\"ed_txt\">University System of Taiwan (UST)</li>\r\n\t<li class=\"ed_txt\">Companies participate in the&nbsp;academia-industry cooperation center of NYCU</li>\r\n</ul>\r\n\r\n<div class=\"ed_txt\"><strong>Instruments are charged per half hour, and the billing will be counted at the end of each odd-numbered month. </strong>Please bring the bill to the Cashier&#39;s Section of the Administration Building within two weeks at the latest. The service will be stopped if the number of overdue payments reaches (and includes) two times.</div>\r\n</div>","page6Title":"Precautions","page6":"<!-- 注意事項 -->\r\n<div class=\"ed_model01 clearfix\">\r\n<ol>\r\n\t<li class=\"ed_txt\"><strong><span style=\"color:#e74c3c;\">No USB flash drive is allowed. </span></strong>Please use FTP to transfer files or bring your blank CD-ROM to burn data. Due to the limited space of the computer&#39;s hard disk, the administrator will delete the data from time to time to facilitate the normal operation of the instrument. <span style=\"color:#e74c3c;\">We are not responsible for data storage.</span></li>\r\n\t<li class=\"ed_txt\"><strong>Without the consent of the administrator of the Center, you are not allowed to add or remove any parts, alter the system settings, or install software on the Center&#39;s public equipment. </strong>If any experiment requires any test, the administrator&#39;s consent must be sought first and accompanied by the engineer of the original manufacturer to carry out the testing without damaging the normal operation of the equipment, and only after the passing of the test can it be operated and used by the personnel approved by the administrator of the Center under the condition of the administrator&#39;s permission.</li>\r\n\t<li class=\"ed_txt\">According to the administrator&#39;s judgment, the violator is warned for the first time, canceled the right to use for one month for the second time, and canceled the right to use permanently for the third time; if the violator violates the above specification, resulting in the damage of the instrument, the violator shall pay compensation to repair the instrument and stop the right to use for one month. The violator is prohibited from using the instrument permanently.</li>\r\n</ol>\r\n</div>","page7Title":"User Manual and Related Files","page7":"<div class=\"ed_model17 clearfix ed_list\">\r\n<ul>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\">How-to-choose-FL-microscope </span> </span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"/userfiles/ordch/images/20231229170513915.png\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"How-to-choose-FL-microscope(Open New Windows)\"><img alt=\"How-to-choose-FL-microscope\" src=\"/userfiles/file/image.png\" /> </a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\">Certification-form-FL_2022 </span> </span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"https://www.nycu.edu.tw/ord/en/app/artwebsite/doc?module=artwebsite&amp;detailNo=1169204295451545600&amp;type=s\" target=\"_blank\" title=\"Certification-form-FL_2022(Open New Windows)\"><img alt=\"Certification-form-FL_2022\" src=\"/userfiles/file/pdf.png\" /> </a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><strong><span style=\"vertical-align: inherit;\">User Manual&nbsp;(English version)</span></strong></span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li>&nbsp;</li>\r\n\t\t<li><a href=\"/userfiles/ordch/files/20231012140013821.pdf\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Instrument Operation Manual:Chinese Version,English manual(pdf)(Open New Windows)\"><img alt=\"Instrument Operation Manual:Chinese Version,English manual\" src=\"/userfiles/file/pdf.png\" /> </a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\">CellSens Manual：English version&nbsp;from Olympus </span> </span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"/userfiles/ordch/files/20231012140122482.pdf\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"CellSens：English manual from Olympus(pdf)(Open New Windows)\"><img alt=\"CellSens：English manual from Olympus\" src=\"/userfiles/file/pdf.png\" /> </a></li>\r\n\t</ul>\r\n\t</li>\r\n</ul>\r\n</div>","page8Title":null,"page8":null,"docs":[],"images":[{"fileurl":"https://ord.nycu.edu.tw/ord/en/app/machine/image?module=machine&detailNo=1164433495410348032&init=Y","expFile":"Olympus BX63"}],"videos":[],"audios":[],"resources":[{"relateURL":"https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&id=2023&serno=da69be39-dc4e-48d6-9168-7c96b2dbdb6e","relateName":"Instrument List of YM Campus"},{"relateURL":"https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&id=2024&serno=df4f722b-8c61-4ccb-92d3-1135d8d1bfe2","relateName":"Imaging Core of YM Campus"},{"relateURL":"https://ord.nycu.edu.tw/ord/en/app/machine/list?module=machine&id=2032","relateName":"Other Fluorescence Microscopes"}]}