<MachineOpenDataModel><subject>&lt;![CDATA[[Guangfu] Cryofree Dilution Refrigerator System]]&gt;</subject><detailContent>&lt;![CDATA[&lt;style type="text/css">.ed_pic_right img,&#xd;
    .ed_pic img {&#xd;
        max-height: 400px;&#xd;
    }&#xd;
&lt;/style>&#xd;
&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="Liquid helium-free dilution refrigeration system" src="/userfiles/ordch/images/20231017102258896.jpg" />&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;strong>Cryofree dilution refrigerator system&lt;/strong>,&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Abbreviation: Dilution refrigerator&lt;/li>&#xd;
		&lt;li class="ed_txt">Brand &amp;amp; model: Oxford, Triton 300&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Expert: Prof.&amp;nbsp;Lo, Shun-Tsung&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Extension 56130&lt;/li>&#xd;
		&lt;li class="ed_txt">Mailbox&amp;nbsp;&lt;a href="mailto:stlo@nycu.edu.tw" title="stlo@nycu.edu.tw">stlo@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Operation Technicians:&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>Wu, Pei-Ci&lt;/strong>&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">Extension 56199&lt;/li>&#xd;
			&lt;li class="ed_txt">Mailbox &lt;a href="mailto:mailto:peytsyr42010@gmail.com" title="peytsyr42010@gmail.com">peytsyr42010@gmail.com&lt;/a>&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Location: Room 006, Science Building 3&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2025-06-18</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument brand, model, year of purchase&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Brand: Oxford&lt;/li>&#xd;
	&lt;li class="ed_txt">Model: Triton 300&lt;/li>&#xd;
	&lt;li class="ed_txt">Purchase period: July 2020&lt;/li>&#xd;
&lt;/ul>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;strong>Important Specifications&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Minimum reachable temperature: 10 mK (system temperature)&lt;/li>&#xd;
	&lt;li class="ed_txt">Maximum reachable magnetic field: plus or minus 12 T&lt;/li&gt;&#xd;
&lt;/ul>&#xd;
&lt;/div></page1><page2Title>Service Items and Opening Hours</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Services&lt;/strong>&lt;br />&#xd;
Low temperature and high magnetic field quantum materials/components/circuit measurement&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Opening hours&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Monday to Friday: 9:00~12:00; 13:30~17:00&lt;/li>&#xd;
	&lt;li class="ed_txt">Nights, Saturdays and Sundays: closed&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;/div></page2><page3Title>System Open Level</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>System opening level&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">General working hours: Level D&lt;/li>&#xd;
	&lt;li class="ed_txt">Night and holiday hours: closed&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;u>&lt;strong>Level Description&lt;/strong>&lt;/u>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Level A: Open to students who need to use it. They can operate it on their own after training and assessment.&lt;/li>&#xd;
	&lt;li class="ed_txt">Level B: Each professor nominates one student for training, while the rest operate under those who have been trained. Professors with multiple students using the instrument can request an increase in the number of students receiving training.&lt;/li>&#xd;
	&lt;li class="ed_txt">Level C: The instrument administrator selects several students recommended by the professor to receive training. After passing the assessment, they can self-operate the instrument and be responsible for delegated operation service.&lt;/li>&#xd;
	&lt;li class="ed_txt">Level D: The laboratory&amp;#39;s technical staff only accept delegated services and are unavailable for general use.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model19 clearfix">&#xd;
&lt;div class="table03">&#xd;
&lt;table class="ed_table caption-top" summary="Charge Standard">&#xd;
	&lt;tbody>&#xd;
	&lt;/tbody>&#xd;
	&lt;caption>Charging standards&lt;/caption>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="col">&amp;nbsp;&lt;/th>&#xd;
			&lt;th colspan="2" rowspan="1" scope="col">Delegated operation&lt;/th>&#xd;
			&lt;th colspan="2" rowspan="1" scope="col">Self-operation&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Items&lt;/th>&#xd;
			&lt;td data-th="Delegated operation">Academic unit&lt;/td>&#xd;
			&lt;td data-th="Entrusted operation">Manufacturers and research units&lt;/td>&#xd;
			&lt;td data-th="Self-operated">Academic units&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Manufacturers and research units&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Start-up Cooling Fee&lt;/th>&#xd;
			&lt;td data-th="Delegated operation">NT$3,000&lt;/td>&#xd;
			&lt;td data-th="Delegated operation">NT$5,000&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Not open&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Not open&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Measurement Fee&lt;/th>&#xd;
			&lt;td data-th="Delegated operation">NT$500/hour&lt;/td>&#xd;
			&lt;td data-th="Delegated operation">NT$1,000/hour&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Not open&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Not open&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">particular requirement&lt;/th>&#xd;
			&lt;td data-th="Delegated operation">Additional fee&lt;/td>&#xd;
			&lt;td data-th="Delegated operation">Additional fee&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Not open&lt;/td>&#xd;
			&lt;td data-th="Operation by yourself">Not open&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody&gt;&#xd;
&lt;/table>&#xd;
&lt;br />&#xd;
Note: Academic units refer to colleges and universities.&lt;/div>&#xd;
&lt;/div></page4><page5Title>Management and Usage</page5Title><page5>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Management and Usage Rules:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">This equipment is primarily intended for academic research, with some additional service capabilities. As the sample cooling and rewarming process can be lengthy and time-consuming, it is essential to have a complete planning document and cooperation policy in place.&lt;br />&#xd;
	&amp;nbsp;&lt;/li>&#xd;
	&lt;li class="ed_txt">Please note that we cannot be held responsible if the samples are damaged during measurement. You must evaluate the stability and quantity of the relevant samples yourself before proceeding with the testing.&lt;br />&#xd;
	&amp;nbsp;&lt;/li>&#xd;
	&lt;li class="ed_txt">To ensure that everything runs smoothly, please discuss and arrange for the samples to be tested with the person in charge of the equipment at least one month in advance.&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument Training Application: &lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt" style="margin-left: 40px;">&lt;strong>This device is only open to the person in charge of the instrument and the technicians of this laboratory.&lt;/strong>&lt;br />&#xd;
&amp;nbsp;&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument Operation Reservation:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;strong>Prof.&amp;nbsp;Lo, Shun-Tsung&lt;/strong> TEL:03-5712121 #56130&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Wu, Pei-Ci&lt;/strong> TEL:03-5712121 #56199&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page5><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://ord.nycu.edu.tw/ord/en/app/machine/image?module=machine&amp;detailNo=1168823668055216128&amp;init=Y</fileurl><expFile>dilution refrigeration system</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&amp;id=2021&amp;serno=ebdd9934-00ef-4bee-9a8a-11f305100505</relateURL><relateName>Instrument List of Guangfu and Boai Campus</relateName></resources><resources><relateURL>https://www.nycu.edu.tw/ord/en/app/machine/list?module=machine&amp;id=2042</relateURL><relateName>Other Analyzers</relateName></resources></resources></MachineOpenDataModel>