Link to Content Area

NYCU Office of Research and Development

Analyzers

  • Update Date:2025-02-20
  • Units:Instrumentation Resource Center
[Guangfu] High-speed pulse pattern generator: PAM4 PPG
High-speed pulse graphic generator
  • Pulse Pattern Generator, PAM4 PPG
    • Manufacturer: Anlizhi Co., Ltd.
    • Model: MU196020A
  • Instrument Expert: Prof. Chen, Wei-Zen
    • Extension 31976
  • Instrument Operation Technicians: Liu, Yao-Chia
  • Instrument Location: Room 626, Engineering Building 4
Instrument brand, model, year of purchase
Brand: Anlizhi Co., Ltd.
Model: MU196020A
Purchase period: September 2020

Important Specifications
  • High-Quality Waveforms and High-Sensitivity Input: Higher Measurement Efficiency with World-Leading Highest Level Waveform Signal Quality
    • High-speed Tr/Tf of 8.5 ps (20 to 80%)
    • Low Intrinsic Jitter of 170 fs (rms)
    • Low noise and low distortion high-quality data output
    • High Rx performance due to 23-mV input sensitivity and analog bandwidth of >40 GHz
    • Stressed Margin BER of <1E-12
  • High Transmission Capacity and Excellent Expandability: Futureproof Multichannel Expansion for 800G R&D
    • All-in-one support for 512 Gbit/s max. transmission capacity
    • Multichannel expandability 4ch PAM4/NRZ
    • 8 slots for module addition
    • Jitter and noise module expandability
    • Operation baud rates of 2.4 Gbaud to 58.2 Gbaud
  • World-First All-in-One PAM4 BER Test Solution: Easy Configuration and Operation without Other External Equipment
    • Supports Emphasis variable dynamic range (±20 dB) and ISI simulation
    • 4-level linearity control
    • Built-in Clock Recovery
    • Jitter and Noise Stress addition
    • PAM4 pattern editor and symbol error measurement
    • Forward Error Correction(FEC) pattern generation
    • Jitter Tolerance measurement using DUT BER counter function
  • Specification Summary
    • Baud rate: 2.4 Gbaud to 58.2 Gbaud (upper limit as option selections)
    • Output amplitude: 0.14 Vp-p to 1.6 Vp-p (Differential)
    • Emphasis: 4 Tap, ±20 dB (1 post/2 precursor), ISI/Channel Emulator
    • Intrinsic jitter(rms): 170 fs (typ., NRZ)
    • Tr/Tf (20-80%) : 8.5 ps (typ., NRZ)
    • Multichannel synchronization
    • FEC pattern generation
Services
Provides 2.4~58Gbd NRZ or PAM-4 pulse pattern signal generation and error analysis. It has standard built-in and manual editing pattern types. It can also add clock jitter and measure JTOL.

Opening Hours
  1. Monday to Friday: 9:00~12:00, 13:30~17:30
  2. Nights, Saturdays and Sundays: Closed
System Opening Level
  1. General working hours: Level D
  2. Night and holiday hours: Closed
Level Description
  • Level A: Open to students who need to use it. They can operate it on their own after training and assessment.
  • Level B: Each professor nominates one student for training, while the rest operate under those who have been trained. Professors with multiple students using the instrument can request an increase in the number of students receiving training.
  • Level C: The instrument administrator selects several students recommended by the professor to receive training. After passing the assessment, they can self-operate the instrument and be responsible for delegated operation service.
  • Level D: The laboratory's technical staff only accept delegated services and are unavailable for general use.
Charging standards
Charging standards Delegated operation Self-operation
Academic Unit NT$2,400/hour Not open
Manufacturers and research units NT$3,000/hour Not open

Note: Academic units refer to colleges and universities.
Management and Usage Methods:
  1. Applicants should submit the experimental plan one week before the measurement.
  2. The laboratory space is limited, and only 2 people can be present for each measurement (including the person who made the reservation). For more than 2 people, please request permission from the measurement engineer in advance.
  3. At the moment of measurement, the applicant conveys the requirements, and all operations are performed by the operation technician.
  4. To enter the laboratory, you must fill in the "Laboratory Entry and Exit Record Book," accurately register the entry and exit times, understand the relevant escape routes, and sign for confirmation.
  5. All food and beverages are prohibited in the laboratory.
Instructions for instrument training operation application: Level D is not open to training operations.

Instrument operation reservation:
Reservation contact information
Name Office Room E-mail
Liu, Yao-Chia ED306 yaochia181@gmail.com
gotop