Cryogenic Cathodoluminescence System
 
低溫陰極螢光分析系統
 
Cryogenic Cathodoluminescence System
  • English abbreviation: CL
  • Brand Model: Attolight Allalin TRCL
Instrument expert:
Instrument consultant:
Instrument consultation and operation service: Dr. Stefan Todorov Petrov
Instrument location:Room SC023, Science Building 3 , Guanfu Campus
Instrument Information:
  • Brand: Attolight
  • Model: Allalin TRCL
  • Year of purchase: 2025
Function:
In addition to low-temperature cathode fluorescence analysis, it also has time-resolution capabilities, which can obtain dynamic spectral information with nanometer/picosecond spatial/time resolutions to enable the study of carrier dynamics and lifetime.

Important Specifications:
  • Acceleration voltage: 2 - 10 kV
  • Large FoV: 300 µm-diameter
  • Detection range: 200 - 1060 nm (CCD); 200-650 nm (PMT)
  • Spatial resolution:
    • CW e-beam: < 10 nm (3-10keV)
    • Pulsed e-beam: ~50 nm on average
 Service items
  • Room temp. cathodoluminescence
  • Low temp./temp. dependence cathodoluminescence
  • Time-resolved Cathodoluminescence
System opening level
  • Working hours:Level D
  • Nights and holidays:No service
System open level description
  • Level A: Open to students who need to use it. They can operate it on their own after training and assessment.
  • Level B: Each professor assigns one student to apply for training. The other students of the professor must be operated by the trained students. If a professor has too many students using the instrument, he or she may apply to the person in charge of the instrument to increase the number of students receiving training. .
  • Level C: The person in charge of the instrument selects a number of students recommended by the professor to receive training. After passing the assessment, they can operate the instrument themselves and be responsible for entrusted service work.
  • Level D: The technical staff of this laboratory accept entrusted services and are not open for use.
Charges (NTD)
Billing items Reservation with NSTC project Reservation without NSTC project
Entrusted Service Self-operation Entrusted Service Self-operation
Room temp. cathodoluminescence 300/hr - 3000/hr -
Low temp./temp. dependence cathodoluminescence 800/hr - 8000/hr -
Opening hours
  Morning Afternoon
Monday to Friday 08: 30 -12: 30 13 : 30 - 17:30
Weekend No service No service
Reservation instructions:
  • Link for reservation: https://vir.nstc.gov.tw/home/Index
  • Pre-experiment consulting line:
  • Open for reservations: 10:00 AM on the 25th of each month / Available reservations period: 1 month / Reservation should be executed at least 3 days in advance (except weekends and holidays).
Service schedule: 8 hours/day, 5 days/week
  •   Note: Every day, 8:30-9:00 and 17:00-17:30 are dedicated to system maintenance.
Reservation cancellations:
  • Cancellations are only available by informing the technician at least 24 hours before the experiment schedule.
  • Please also mention the reasons for cancellation in the email.
  • If the users cancel their reservations late, their reservation license will be suspended for one month from the day of cancellation.
  • Accumulating 3 times of late cancellation per year, the reservation license will be suspended for six months from the day of the last cancellation.
Others:
  • If the reservation schedule conflicts with the training schedule, the training schedule will take priority.
  • If the reservation schedule conflicts with the manufacturer's maintenance schedule, the manufacturer's maintenance schedule will take priority.
  • To maintain the cleanliness of the experiment condition, no food or drinks are allowed in the laboratory.
Currently, the CL system does not open for user training.